Troubleshooting steps for an AF-6710 display
Topic
- How do I troubleshoot an unresponsive AF-6710?
Environment
- Product Family: Transportation
- Product: Dak Ireland AF-6710 data display
- Components: SBC, ILCS2 Image controller, Globus Cluster controller, PSU, Module
- Control System: DVS software
Steps
- Ensure the video cable is secure from the SBC to the Image controller. Check that the power connections to the image controller are secure and providing proper voltage.
- Check the Ethernet cables between the image controller and the cluster controller(s). Ensure the cluster controllers are powered. Ensure the Ethernet cables on the cluster controllers are connected.
- Check each ribbon cable from the cluster controllers to the LED boards (modules). Check both the input and output cables. Check that the LED boards are receiving power.
- It is possible for a faulty LED board to disrupt the data signal. Try removing each board one by one and note any change in behavior.
- When checking LED boards, unseat the ribbon cable and reset it. Check that the cable is oriented correctly in the connector (Even though the cable is keyed for the connector, it possible with enough force to push the cable in backwards.)
- If an LED board seems to be faulty, try swapping it with a good board. You want to see if the issue follows the board in question, in which case you can conclude it's the board.
- Use a meter to check the voltage of the power supplies. The proper voltage is written on a label on the PSU to check against.
- If you are unable to resolve the issue, contact tech support at 1-800-833-3157.
- Take pictures of the internal components and connections for reference.
- Key Terms:
- SBC= Single Board Computer
- PSU= Power Supply Unit
- DVS= Data Vision Software
- Module= LED board
- Image controller - ILCS2 controller, both are the same thing
- Globus controller - Cluster controller, both are the same thing
KB ID: DD3653612
DISCLAIMER: Use of this content may void the equipment warranty, please read the disclaimer prior to performing any service of the equipment.
DAKTRONICS DOES NOT PROMISE THAT THE CONTENT PROVIDED HEREIN IS ERROR-FREE OR THAT ANY DEFECTS WILL BE CORRECTED, OR THAT YOUR USE OF THE CONTENT WILL PROVIDE SPECIFIC RESULTS. THE CONTENT IS DELIVERED ON AN "AS-IS" AND "AS-AVAILABLE" BASIS. ALL INFORMATION PROVIDED IN THIS ARTICLE IS SUBJECT TO CHANGE WITHOUT NOTICE. DAKTRONICS DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF ACCURACY, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DAKTRONICS DISCLAIMS ANY AND ALL LIABILITY FOR THE ACTS, OMISSIONS AND CONDUCT OF YOU OR ANY THIRD PARTIES IN CONNECTION WITH OR RELATED TO YOUR USE OF THE CONTENT. ADJUSTMENT, REPAIR, OR SERVICE OF THE EQUIPMENT BY ANYONE OTHER THAN DAKTRONICS OR ITS AUTHORIZED REPAIR AGENTS MAY VOID THE EQUIPMENT WARRANTY. YOU ASSUME TOTAL RESPONSIBILITY FOR YOUR USE OF THE CONTENT AND ANY LINKED CONTENT. YOUR SOLE REMEDY AGAINST DAKTRONICS FOR DISSATISFACTION WITH THE CONTENT IS TO STOP USING THE CONTENT. THIS LIMITATION OF RELIEF IS A PART OF THE BARGAIN BETWEEN THE PARTIES.