Display: Blank Section or row, entire display, or mirror is blank, Failed power supply

Potential Symptoms

  • Individual, portion, section, line, or block of modules blank on display; may include multiple rows and columns of modules.
    • Modules further down the signal stream from the blank modules may be blank, showing solid colors, pixelated, or other garbled images. 
  • Entire display (or mirror side) may be blank or garbled depending on display size and component layout.
    • However, still able to communicate to the display (Galaxy and GalaxyPro only).
  • Half or segment of the display may be blank depending on display size and component layout.
  • Section of modules may flash on and off or flicker.
  • No power LED lit on the modules connected to the power supply.
  • Power supply is not outputting correctly but is receiving proper voltage, typically 120, 208 or 240 VAC.
  • Blank section of modules.
  • Communication Failure event on the affected modules in IDM.
  • Possible Communication Failure event on affected MLC's or DD's in IDM.
  • IDM reports all modules in section as "Reset" when power goes off then back on.
  • If the fans in the display are DC powered (e.g. DB-2000 or DB-3000), the fans located in the correlating power supply section will not be running.

Environment

  • Product: Billboard: DB-1000, DB-2000, DB-3000, DB-4075, DB-4100, DB-4200, DB-5000, DB-6400, DB-6500, BLD-0100; Galaxy:AF-3010, AF-3020, AF-3050, AF-3060, AF-3080, AF-3090, AF-3150, AF-3160, AF-3180, AF-3190, AF-3197, AF-3200, AF-3220, AF-3400, AF-3500, AF-3550; GalaxyPro: AF-3700, GPC, GPR (Revolution); ProStar Video Displays (Also, RTX, ProAd), Sport Star Live (SSL), SportStar (SS), Ticker-KF-1010 Series, GS6, GT6, DVX
  • Component: Module, modular power supply
  • Control System:

Cause

  • Failed power supply.

Resolution

  • Replace the failed power supply.

For Temporary Operation

  • If a spare power supply is not available, swap the failed power supply with another to minimize the visual impact to the display.
    • Galaxy example: Swap a working power supply from mirror face that is working to the primary face where the failed power supply is located.
    • Billboard and video example: Swap a working power supply from the corner or edge of the display, one that powers fewer modules.

KB ID: 000007727


DISCLAIMER: Use of this content may void the equipment warranty, please read the disclaimer prior to performing any service of the equipment.

DAKTRONICS DOES NOT PROMISE THAT THE CONTENT PROVIDED HEREIN IS ERROR-FREE OR THAT ANY DEFECTS WILL BE CORRECTED, OR THAT YOUR USE OF THE CONTENT WILL PROVIDE SPECIFIC RESULTS. THE CONTENT IS DELIVERED ON AN "AS-IS" AND "AS-AVAILABLE" BASIS. ALL INFORMATION PROVIDED IN THIS ARTICLE IS SUBJECT TO CHANGE WITHOUT NOTICE. DAKTRONICS DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF ACCURACY, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DAKTRONICS DISCLAIMS ANY AND ALL LIABILITY FOR THE ACTS, OMISSIONS AND CONDUCT OF YOU OR ANY THIRD PARTIES IN CONNECTION WITH OR RELATED TO YOUR USE OF THE CONTENT. ADJUSTMENT, REPAIR, OR SERVICE OF THE EQUIPMENT BY ANYONE OTHER THAN DAKTRONICS OR ITS AUTHORIZED REPAIR AGENTS MAY VOID THE EQUIPMENT WARRANTY. YOU ASSUME TOTAL RESPONSIBILITY FOR YOUR USE OF THE CONTENT AND ANY LINKED CONTENT. YOUR SOLE REMEDY AGAINST DAKTRONICS FOR DISSATISFACTION WITH THE CONTENT IS TO STOP USING THE CONTENT. THIS LIMITATION OF RELIEF IS A PART OF THE BARGAIN BETWEEN THE PARTIES.