How to configure a Moxa Ethernet I/O for a VFC or VC6

Topic

  • How do I configure a remote Ethernet I/O for a VF or VC6 display?
  • How do I setup an over height switch utilizing a Moxa Ethernet I/O?

Environment

  • Product Family: Transportation
  • Product: Vanguard
  • Components: VFC, DMP-5050, DMP-8050
  • Control System: Local control, Vanguard Professional Software

Steps

Upload the correct firmware to the controller

  1. Upload/install the newest player (DMP) firmware to the controller..

Configure the ETHERNET I/O

Option 1: Configuring the I/O locally on the VFC or through the NTCIP interface of the DMP

  1. Log into the NTCIP page of the DMP, or into the VFC locally.
  2. Select SHARED
  3. ETHERNET I/O
  4. CHANGE DEVICE
  5. MOXA IOLOGIK E1212
  6. Cancel back to the previous menu and select IP ADDRESS.
  7. Enter the IP address of the I/O.  (Default: 192.168.127.254) NOTE: Depending on the network the IP addresses may have to be within the same subnet.  The controllers IP and the IO IP can be changed within their respective web interfaces. (controllers IP address needs to be similar to the I/O)
  8. Cancel back from the previous menu and select PORT
  9. Enter the I/O port.  (Default: 502)
  10. Cancel back from the previous menu and select ENABLE
  11. Select ENABLE

Option 2: Configure the I/O through the webpage interface.

  1. Go to: http://controllerIP/io/#/config (Replace controllerIP with the IP of the controller.)
    • Note older firmware will use http://controllerIP/io/config.html
  2. Make sure Enabled and ERTD is on
  3. Select add device  VS6 MOXA 3.PNG
  4. Add the IP of the Moxa.
  5. Set the port to 502.
  6. Then in drop down select Moxa(TM) iologik E1212vs6 MOXA 5.PNG 
  7. Verify the Poll Rate and Timeout values are set to "0".
  8. Select Save
  9. IMPORTANT: If you set a password on the Moxa, add the password by selecting the Key icon (left side of screen) on the I/O services Dashboard page.  URL example: 10.10.10.10/io/#/devices/0/credentialVS6 MOXA 6.PNG
    VS6 MOXA 7.PNG
  10. There should be no username for this - leave it blank
  11. After entering the password, click on SAVE 

 

Configure the Over Height switch (optional)

  1. Log into the VFC locally, or through the NTCIP interface on the DMP.
  2. Select SIGN 1
  3. CONFIGURATION
  4. PERIPHRIAL
  5. ADD
  6. ADVANCED SETUP
  7. ADD OVER HEIGHT DETECTOR
  8. ETHERNET I/O 1
  9. CONTROL PIN: 1
  10. Select what you would like the sign to do when the over height is triggered.


*NOTE:  If configuring for a Binary or BCD (Binary Count Decimal) switch in the VFC, there is a limit of  a maximum of  8 DI (inputs).

KB ID: DD3709979


DISCLAIMER: Use of this content may void the equipment warranty, please read the disclaimer prior to performing any service of the equipment.

DAKTRONICS DOES NOT PROMISE THAT THE CONTENT PROVIDED HEREIN IS ERROR-FREE OR THAT ANY DEFECTS WILL BE CORRECTED, OR THAT YOUR USE OF THE CONTENT WILL PROVIDE SPECIFIC RESULTS. THE CONTENT IS DELIVERED ON AN "AS-IS" AND "AS-AVAILABLE" BASIS. ALL INFORMATION PROVIDED IN THIS ARTICLE IS SUBJECT TO CHANGE WITHOUT NOTICE. DAKTRONICS DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF ACCURACY, NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DAKTRONICS DISCLAIMS ANY AND ALL LIABILITY FOR THE ACTS, OMISSIONS AND CONDUCT OF YOU OR ANY THIRD PARTIES IN CONNECTION WITH OR RELATED TO YOUR USE OF THE CONTENT. ADJUSTMENT, REPAIR, OR SERVICE OF THE EQUIPMENT BY ANYONE OTHER THAN DAKTRONICS OR ITS AUTHORIZED REPAIR AGENTS MAY VOID THE EQUIPMENT WARRANTY. YOU ASSUME TOTAL RESPONSIBILITY FOR YOUR USE OF THE CONTENT AND ANY LINKED CONTENT. YOUR SOLE REMEDY AGAINST DAKTRONICS FOR DISSATISFACTION WITH THE CONTENT IS TO STOP USING THE CONTENT. THIS LIMITATION OF RELIEF IS A PART OF THE BARGAIN BETWEEN THE PARTIES.